Ningbo Richge Technology Co., Ltd.
Ningbo Richge Technology Co., Ltd.
Products
AC / AD / ACD / ACA / ACJ Series Hydraulic Shock Absorber
  • AC / AD / ACD / ACA / ACJ Series Hydraulic Shock AbsorberAC / AD / ACD / ACA / ACJ Series Hydraulic Shock Absorber
  • AC / AD / ACD / ACA / ACJ Series Hydraulic Shock AbsorberAC / AD / ACD / ACA / ACJ Series Hydraulic Shock Absorber
  • AC / AD / ACD / ACA / ACJ Series Hydraulic Shock AbsorberAC / AD / ACD / ACA / ACJ Series Hydraulic Shock Absorber

AC / AD / ACD / ACA / ACJ Series Hydraulic Shock Absorber

SOLH AC, AD, ACD, ACA and ACJ hydraulic shock absorbers are fully compatible with Airtac specifications, model coding and installation dimensions for seamless replacement. This product range includes fixed multi-orifice, manually adjustable, bidirectional, auto-compensation and adjustable auto-compensation types, catering to simple cylinder buffering, variable load conditions, forward-reverse robotic transfer and high-frequency precision automation. A wide selection of thread sizes, buffer strokes and impact caps (plastic, iron or capless) helps absorb impact energy, suppress vibration and noise, and protect mechanical structures from collision damage, supporting bulk equipment cost optimization with stable delivery.
    Rating: 5.0
    (Rating Count: 1)

    SOLH AC / AD / ACD / ACA / ACJ Series Hydraulic Shock Absorber | Pneumatic Dashpot

    Brand: SOLH by Richge Technology | Airtac Equivalent Hydraulic Shock Absorber



    1. Product Overview

         SOLH AC / AD / ACD / ACA / ACJ series hydraulic shock absorbers are mainstream pneumatic buffer dampers, fully compatible with Airtac model coding, mounting dimensions and performance parameters. Direct drop-in replacement for imported buffers, with competitive cost and shorter lead time for volume machine cost reduction.

         This family covers fixed damping, adjustable damping, bidirectional buffer and auto-compensation types, widely used for cylinder end cushioning, robotic transfer mechanism, rotary actuator, automation fixture and high-speed handling equipment to absorb kinetic impact and reduce vibration, noise and mechanical collision damage.

    2. Model Naming Rule: AC / AD / ACD Series

    Example: AC1416-1N

    Position

    Code

    Meaning

    Description

    1

    AC / AD / ACD

    Series Code

    AC: Fixed multi-orifice (non-adjustable)
    AD: Adjustable damping with regulator
    ACD: Bidirectional shock absorber, robot dedicated

    2

    14

    Thread Size

    Outer thread of housing, e.g. 14 = M14×1.5

    3

    16

    Stroke

    Buffer stroke in mm, range 6~150mm; 16 = 16mm stroke

    4

    1

    Impact Speed / Load Grade

    1: High speed / light load
    2: Medium speed  medium load
    3: Low speed  heavy load

    5

    N

    Buffer Cap

    Blank: Standard with buffer cap
    N: Without buffer cap

    3. Model Naming Rule: ACA / ACJ Series

    Example: ACA2020-1N

    Position

    Code

    Meaning

    Description

    1

    ACA / ACJ

    Series Code

    ACA: Auto-compensation type, non-adjustable
    ACJ: Adjustable auto-compensation type with damping knob

    2

    20

    Thread Size

    Housing thread: 08=M8,10=M10,12=M12,14=M14,16=M16,20=M20,25=M25,27=M27

    3

    20

    Stroke

    Buffer stroke in mm; 20 = 20mm stroke

    4

    1

    Speed Grade (ACA only)

    1: High speed / light load
    2: Medium speed  medium load
    3: Low speed  heavy load
    ACJ has no speed code, damping adjusted by rear knob

    5

    N / F

    Impact Cap

    Blank: Standard plastic cap
    F: Iron cap for heavy duty wear
    N: No impact cap

    4. Series Comparison Chart

    Series

    Damping Adjustment

    Core Features

    Typical Application

    AC

    Non-adjustable

    Fixed multi-orifice, low cost, ready to mount

    Cylinder end buffer, general-purpose budget applications

    AD

    Adjustable

    Rear adjustment knob, on-site damping tuning

    Variable working conditions, changing load & speed

    ACD

    Non-adjustable

    Bidirectional impact absorption, both ends buffered

    Robot arms, rotary units, high-speed transfer, forward & reverse motion

    ACA

    Non-adjustable

    Auto-compensation, good sealing, long service life, standard automation grade

    Standard cylinder, stable buffer for automation equipment

    ACJ

    Adjustable

    Adjustable damping + auto-compensation, widest adaptability, premium performance

    High frequency, high speed, heavy load, precision equipment requiring fine tuning

    5. Model Interpretation Examples

         • AC1416-1N: Fixed multi-orifice, M14 thread, 16mm stroke, high-speed light load, without buffer cap

         • AD2020-2: Adjustable type, M20 thread, 20mm stroke, medium speed medium load, standard buffer cap included

         • ACD1630: Bidirectional shock absorber, M16 thread, 30mm stroke (no speed & cap suffix)

         • ACA1412-2: Auto-compensation non-adjustable, M14 thread, 12mm stroke, medium speed medium load, plastic impact cap

         • ACJ2020-F: Adjustable auto-compensation, M20 thread, 20mm stroke, iron heavy-duty impact cap (no speed code)

    6. Selection & Operation Guidelines

         1. Select series first: Confirm whether damping adjustment and bidirectional buffer are required according to working complexity

         2. Match thread and stroke: Thread size must fit mounting hole; buffer stroke must be shorter than total mechanism travel to avoid hard bottom collision

         3. Speed & load matching: ACA models select grade 1/2/3 by speed and load; AC/AD/ACD are pre-engineered for rated condition

         4. Impact cap selection: Plastic cap for general use; iron cap for heavy load / high frequency; N type no-cap when space is limited

         5. Installation note: Apply small amount of anaerobic thread locker, PTFE tape is forbidden. Manually test after installation to ensure smooth piston movement without sticking

    7. Replacement Note

         SOLH AC/AD/ACD/ACA/ACJ shock absorbers adopt identical naming convention, mounting dimensions and performance curve as Airtac. Direct drop-in replacement for imported dampers, with lower cost and faster lead time, ideal for mass equipment cost-down projects.

    Send Inquiry
    Contact Info
    For inquiries about low voltage switchgear, high voltage insulators, high voltage earthing switch or price list, please leave your email to us and we will be in touch within 24 hours.
    Rating:
    5.0
    X
    We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
    RejectAccept