Richge is a professional manufacturer and supplier in China. Our factory provides low voltage switchgear, low voltage panels, metal clad switchgear, etc. If you are interested in our products, you can inquire now, and we will get back to you promptly.
FKN12-12D series air-blast Ioad break switch and FKRN12-12D series air-blast load break switch-fuse combination apparatus are new series switchgear applies to three-phase electric distribution system of rated 12kV, acting as protecting and control apparatus for transformers, cable and overhead wiring. These series are especially applicable in rural, urban terminal substation and prefabricated substations, as well as ring network power supply. FKN12-12D can break and make Ioad current and over-current. FKRN12-12D can break and make over-current load current and short-circuit current(Iimited current fuse). This product is featured with impact structure aesthetic appearance. reliable interlock and high insulating level. In the spring storage operation mechanism, ON/OFF speed is free from the influence of the manpower. For the arc-extinguish, electric arc-extinguish inside the insulating cover, the free gas occurs at sparking do not cause descend of insulating level between phases and phase to earth. The insulation cover clapboard separates electrified part thus boost protection grade of ring main unit. The copper-tungsten contact and main contact brings along reliable conductivity and long life. This product achieves sound fame due to easy maintenance and operation as well as reliable performance. It is in compliance with IEC62271-105.
FZRN21 series Ac and HV indoor vacuum load break switch, this product has a breaking capacity, safety and reliability, long life, can operate freguent, compact structure, small size, light weight, the basic no need to maintain.
FZN21-12 series high-voltage vacuum load switch is mainly composed of framer, disconnecting switch (current-limiting fuse of the combiner is in the disconnecting switch), vacuum switching tube, grounding switch, spring operating mechanism and so on. This product has compact structure, small volume, long life, strong closing and breaking capacity, and easy operation and maintenance. The vacuum switch is equipped with a spring-operated mechanism, which adopts an electric motor (another manual) spring energy storage, and there are two types of closing methods: electromagnet closing and manual splitting and closing. The disconnecting switch, vacuum switch and earthing switch are interlocked with each other (mechanical interlocking) to prevent misoperation.
FZN21-12D/T630-20, FZN21-12DR/T125-31.5 type high-voltage vacuum load break switch and fuse switch are operating in three-phase AC electrical 12kV, 50Hz power distribution system, with a compact, small size, light weight, long service life, high making and breaking ability, safe and reliable, and if load switch cooperated with fuse namely fuse switch can replace those fuses with higher cost, easy and convenient operation and maintenance
Sulphur hexafluoride (SF6) is a good gas insulator. Its typical application is gas insulation in high-voltage switchgear of power supply systems. When the sulphur hexafluoride gas encounters high heat and high temperatures(e.g. arc), it produces hydrogen fluoride and sulphur dioxide gases, which coexist with undecomposed sulphur hexafluoride gases. The rated pressure of the SF6 high voltage circuit breaker is usually 0. 0.6 MPa(table pressure). The pressure of the SF6 gas must be checked against the temperature curve of the product when inflating or checking the temperature curve.
FLN36-12kV SF6 load break switch is a switch equipment for medium voltage switchgear, using SF6 gas as arc extinguishing and insulating medium. There are three working positions: open, closed, earth position in the switch. The compact size, easy installation, and fine adaptability to environment make the switch suitable for many different applications.
Newly developed load break switch, applied on SF6 RMU. With features of high efficiency, safety, reliability, simple structure, flexible operation, interlock reliable, easy to install and so on. It satisfies with standard IEC94, GB3804, GB16926 and so on.
The FL(R)N36 Indoor AC High Voltage SF6 Load Break Switch and LBS-Fuse Combination are designed for use in three-phase AC 50/60Hz RMUs (Ring Main Units) and terminal power stations. These switches are suitable for protecting power systems operating at 10kV, 24kV, and 35kV under on-load conditions. They are capable of interrupting on-load current, closed-loop current, no-load transformer capacity, and cable charging current. When equipped with a fuse combination, they can cut off any current within the range of the rated short-circuit breaking current. These devices find application in RMUs and combined transformers, among others.
The company mainly develops and produces oil-immersed transformers, dry-type transformers, box-type substations, high-voltage switches, and medium and low voltage complete sets of equipment. The equipment put into production and operation of the project advocates energy saving, intelligence, informatization, and mechanization. Twith 71 utility model patents and 15 invention patents. With years of accumulation in the transformer industry and strong technological innovation capabilities, HZEC products are sold to the Middle East, North America, South America, Europe, Southeast Asia, Africa, and other regions, covering more than 40 countries.Description
The company mainly develops and produces oil-immersed transformers, dry-type transformers, box-type substations, high-voltage switches, and medium and low voltage complete sets of equipment. The equipment put into production and operation of the project advocates energy saving, intelligence, informatization, and mechanization. Twith 71 utility model patents and 15 invention patents. With years of accumulation in the transformer industry and strong technological innovation capabilities, HZEC products are sold to the Middle East, North America, South America, Europe, Southeast Asia, Africa, and other regions, covering more than 40 countries.Description
FLN36-12D/FLRN36-12D type indoor AC high voltage SF6 load break switch is suitable for three-phase 50Hz ring network or terminal power supply and industrial electrical equipment, for protecting the line of 10kV Electric Power Load Control System.
FLN36-24D load break switch use SF6 gas as arc extinguishing and insulating medium. There are three work stations: opening, closing and grounding in the switch. It has small volume, installing easy-to -use, strong environmental adaptabiliy and other characterist.
FLN36-12(24)D/630-20 Indoor AC High Voltage SF6 Load Break Switch and FLRN36-12(24)D/100-31.5 Indoor AC High Voltage SF6 Load Break Switch-Fuse Combination are used for the three-phase AC 50/60Hz RMU and terminal power station. The switches are suitable for protecting the 10kV, 24kV and 35kV power systems in load situations. The switch can switch off the on-load current, closed loop current, no-load transformer capacity and cable charging current. The switch with fuse combination can cut off any current when the current is in the range of the rated short-circuit breaking current. They are suitable for the RMU, combined transformer, etc.
FLN36-40.5D/T630 indoor sulfur hexafluoride (SF6) load switch and FLN36-40.5DR/125 load switch fuse combination are suitable for power stations and industrial electrical equipment with three-phase AC 50/60Hz ring network or terminal power supply. They are used as load control line protection for power systems. The load switch divides and closes load current, closed-loop current, no-load transformer and cable charging current; Combination electrical appliances can break any current under rated short-circuit current and are suitable for electrical complete sets of equipment such as ring main units and box type substations.
FLN36-40.5 load break switch and FLN -40.5D load break switch plus fuse combination, can be used to protect and control the electric equipments for power supply and transformer substations, which is especially suitable for ring net cabinet, cable branch cabinet and distribution switching substation.
FLN48-12 load break switch use SF6 gas as arc extinguishing and insulating medium. There are three work stations: opening, closing and grounding in the switch. It has small volume, installing easy-to -use, strong environmental adaptabiliy and other characterist.. It is also for the control and protection of substation and equipments; making and breaking short-circuit current under various operating status of electric network
and its performance indicators meet the national standard GB/T3804-2017 "3.6kV-40.5kV high-voltage AC load switch", which is the main switching element of the ring main unit.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies.
Privacy Policy