      We are committed to developing Load Switch, Outdoor High Voltage Auto Recloser, Indoor Voltage Vacuum Breaker that are closer to the needs of consumers and provide consumers with better products. We always take rewarding society as a blessing and take the prosperity and revitalization of the motherland as our own responsibility. Our company takes our enterprise reputation and staff quality ahead of enterprise development as our development guarantee. We insist on the idea of science and technology is the first productive force. With our technical skils, efficient management and high-quality products, we have won praise from our customers with our cost-effective goods.


      Here is a brief introduction to Vacuum Circuit Breaker (VCB), Load Break Switch (LBS), SF₆ Gas Circuit Breaker, Outdoor Circuit Breaker, and Indoor Vacuum Circuit Breaker, covering their core features, principles, and applications:


Vacuum Circuit Breaker (VCB)

Definition: A switching device using high vacuum (vacuum degree ≥10⁻⁴ Pa) as the arc-extinguishing and insulating medium, which is the mainstream equipment in medium and high-voltage fields.

Core Principle: When the contacts separate in a vacuum, the arc is quickly extinguished (within 0.01~0.02 seconds) due to the lack of gas medium to sustain it.


Features:

    1.Strong arc-extinguishing performance and long mechanical life (up to 100,000 operations or more);

    2.No oil or SF₆, environmentally friendly and safe, with minimal maintenance;

    3.Compact size and light weight, suitable for tight spaces.

    4.Applications: 10kV~35kV medium and high-voltage systems, such as substations, industrial power distribution, and new energy grid connection.



 Load Break Switch (LBS)

Definition: A switching device mainly used to switch on and off normal operating current (load current). It cannot interrupt short-circuit current (relying on fuses or circuit breakers for short-circuit protection).

Core Principle: It can extinguish small arcs (e.g., those generated by load current) during switching, but its arc-extinguishing capacity is limited.


Features:

   1.Simple structure, low cost, and easy operation;

   2.Single function, only used for normal load control, requiring external protection (e.g., fuses).

   3.Applications: Low-voltage (0.4kV) or medium-voltage (6~10kV) distribution branches, such as community power distribution and on-off control of small industrial loads.



SF₆ Gas Circuit Breaker

Definition: A high-voltage switching device using sulfur hexafluoride (SF₆) gas as the arc-extinguishing and insulating medium. SF₆ has strong insulation (about 2.5 times that of air) and arc-extinguishing ability.

Core Principle: SF₆ gas decomposes into low-conductivity substances under arc high temperature and quickly recombines after cooling, efficiently extinguishing the arc.


Features:

   1.Extremely strong arc-extinguishing capacity, suitable for high voltage levels (110kV and above) and large current scenarios;

   2.Relatively compact, but SF₆ is a potent greenhouse gas (with a high Global Warming Potential value), requiring strict recycling to avoid leakage.

   3.Applications: 220kV and above ultra-high voltage, extra-high voltage substations, such as main power grid lines and large power plant outlets.



Outdoor Circuit Breaker

Definition: A circuit breaker designed specifically for outdoor environments, capable of withstanding harsh conditions such as wind, rain, temperature extremes, pollution, and ultraviolet radiation.

Core Features:

   1.High protection rating (e.g., IP65 and above), with enclosures made of weather-resistant materials (e.g., stainless steel, reinforced plastic);

   2.Enhanced insulation design (e.g., extended creepage distance) to adapt to outdoor humid and polluted environments;

   3.Arc-extinguishing medium can be vacuum or SF₆ (selected based on voltage level: vacuum for medium voltage, SF₆ for high voltage).

   4.Applications: Outdoor substations, overhead line terminals, outdoor distribution areas of wind/solar power plants, etc.



Indoor Vacuum Circuit Breaker

Definition: A vacuum breaker installed indoors (e.g., in distribution rooms or switchgear), designed for dry and clean indoor environments.

Core Features:

   1.More compact, saving indoor space;

   2.Moderate protection rating (e.g., IP3X), no need to cope with extreme outdoor environments;

   3.Inherits the environmental friendliness and long life advantages of vacuum circuit breakers.

   4.Applications: Indoor substations, industrial plant distribution rooms, building power distribution systems (10~35kV level).



Summary Comparison

Equipment Type
Core Function
Arc-Extinguishing Medium
Typical Voltage Level
Environmental Adaptability
Vacuum Circuit Breaker (VCB)
Interrupt load + short-circuit current
Vacuum
10~35kV
Suitable for both indoor/outdoor
Load Break Switch (LBS)
Only interrupt load current
Air/gas
0.4~10kV
Mainly indoor
SF₆ Gas Circuit Breaker
Interrupt high-voltage and large current
SF₆ gas
110kV and above
Suitable for both indoor/outdoor
Outdoor Circuit Breaker
Adapt to harsh outdoor environments
Vacuum/SF₆
All voltage levels
Exclusive to outdoor
Indoor Vacuum Circuit Breaker
Load + short-circuit protection in compact indoor spaces
Vacuum
10~35kV
Exclusive to indoor

   

   These devices form the control and protection network of power systems based on voltage levels, environmental requirements, and functional positioning.


View as  
 
24KV 230mm Indoor SF6 Load Break Switch lbs switch

24KV 230mm Indoor SF6 Load Break Switch lbs switch

Newly developed load break switch, applied on SF6 RMU. With features of high efficiency, safety, reliability, simple structure, flexible operation, interlock reliable, easy to install and so on. It satisfies with standard IEC94, GB3804, GB16926 and so on. The FL(R)N36 Indoor AC High Voltage SF6 Load Break Switch and LBS-Fuse Combination are designed for use in three-phase AC 50/60Hz RMUs (Ring Main Units) and terminal power stations. These switches are suitable for protecting power systems operating at 10kV, 24kV, and 35kV under on-load conditions. They are capable of interrupting on-load current, closed-loop current, no-load transformer capacity, and cable charging current. When equipped with a fuse combination, they can cut off any current within the range of the rated short-circuit breaking current. These devices find application in RMUs and combined transformers, among others.
40.5KV 230mm Indoor LBS switch SF6 load break switch

40.5KV 230mm Indoor LBS switch SF6 load break switch

The company mainly develops and produces oil-immersed transformers, dry-type transformers, box-type substations, high-voltage switches, and medium and low voltage complete sets of equipment. The equipment put into production and operation of the project advocates energy saving, intelligence, informatization, and mechanization. Twith 71 utility model patents and 15 invention patents. With years of accumulation in the transformer industry and strong technological innovation capabilities, HZEC products are sold to the Middle East, North America, South America, Europe, Southeast Asia, Africa, and other regions, covering more than 40 countries.Description
FLN36-12D/FLRN36-12D SF6 Load Break Switch LBS

FLN36-12D/FLRN36-12D SF6 Load Break Switch LBS

The company mainly develops and produces oil-immersed transformers, dry-type transformers, box-type substations, high-voltage switches, and medium and low voltage complete sets of equipment. The equipment put into production and operation of the project advocates energy saving, intelligence, informatization, and mechanization. Twith 71 utility model patents and 15 invention patents. With years of accumulation in the transformer industry and strong technological innovation capabilities, HZEC products are sold to the Middle East, North America, South America, Europe, Southeast Asia, Africa, and other regions, covering more than 40 countries.Description FLN36-12D/FLRN36-12D type indoor AC high voltage SF6 load break switch is suitable for three-phase 50Hz ring network or terminal power supply and industrial electrical equipment, for protecting the line of 10kV Electric Power Load Control System.
FLN36-24D Indoor High Voltage SF6 Load Break Switch lbs

FLN36-24D Indoor High Voltage SF6 Load Break Switch lbs

FLN36-24D load break switch use SF6 gas as arc extinguishing and insulating medium. There are three work stations: opening, closing and grounding in the switch. It has small volume, installing easy-to -use, strong environmental adaptabiliy and other characterist. FLN36-12(24)D/630-20 Indoor AC High Voltage SF6 Load Break Switch and FLRN36-12(24)D/100-31.5 Indoor AC High Voltage SF6 Load Break Switch-Fuse Combination are used for the three-phase AC 50/60Hz RMU and terminal power station. The switches are suitable for protecting the 10kV, 24kV and 35kV power systems in load situations. The switch can switch off the on-load current, closed loop current, no-load transformer capacity and cable charging current. The switch with fuse combination can cut off any current when the current is in the range of the rated short-circuit breaking current. They are suitable for the RMU, combined transformer, etc.
FLN36-40.5KV Indoor HV SF6 Load Break Switch/LBS sf6

FLN36-40.5KV Indoor HV SF6 Load Break Switch/LBS sf6

FLN36-40.5D/T630 indoor sulfur hexafluoride (SF6) load switch and FLN36-40.5DR/125 load switch fuse combination are suitable for power stations and industrial electrical equipment with three-phase AC 50/60Hz ring network or terminal power supply. They are used as load control line protection for power systems. The load switch divides and closes load current, closed-loop current, no-load transformer and cable charging current; Combination electrical appliances can break any current under rated short-circuit current and are suitable for electrical complete sets of equipment such as ring main units and box type substations. FLN36-40.5 load break switch and FLN -40.5D load break switch plus fuse combination, can be used to protect  and control the electric equipments for power supply and transformer substations, which is especially suitable  for ring net cabinet, cable branch cabinet and distribution switching substation.
FLN48-12 Indoor HV SF6 Load Break Switch lbs

FLN48-12 Indoor HV SF6 Load Break Switch lbs

FLN48-12 load break switch use SF6 gas as arc extinguishing and insulating medium. There are three work stations: opening, closing and grounding in the switch. It has small volume, installing easy-to -use, strong environmental adaptabiliy and other characterist.. It is also for the control and protection of substation and equipments; making and breaking short-circuit current under various operating status of electric network and its performance indicators meet the national standard GB/T3804-2017 "3.6kV-40.5kV high-voltage AC load switch", which is the main switching element of the ring main unit.
LW8-40.5 35kV Outdoor AC High Voltage SF6 Circuit Breaker

LW8-40.5 35kV Outdoor AC High Voltage SF6 Circuit Breaker

The LW8(A)-40.5 outdoor AC SF6 Circuit Breaker is a three-phase, 50Hz outdoor high-voltage electrical device designed for use in power systems with a rated voltage of 40.5 kV. LW8-40.5, LW8A-40.5 series sulfur hexafluoride circuit breakers are three-phase AC 50Hz outdoor high-voltage electrical equipment,suitable for the control and protection of 40.5kV transmission and distribution system, can also be used for connection circuit breakers and open and close capacitor Banks. The product can be used with CT14 spring mechanism. The circuit breaker conforms to the national standard GB1984 -- 1989 AC high-voltage circuit breaker and the international electrotechnical commission standard IEC56, IEC6220-100 high-voltage ac circuit breaker. The product has excellent breaking performance, USES the pressure air type arc extinguishing chamber, the electric life is long, does not replace the sulfur hexafluoride gas, the mechanical reliability is high, the mechanical life is long, can operate frequently; Each set can be equipped with 6-12 current transformers for user's choice. This product adopts the new MKZ model SF6 pointer density meter, the pressure gauge reading is not affected by the temperature change, easy to use.
LW36-126 110kV 126kV Outdoor SF6 Circuit Breaker

LW36-126 110kV 126kV Outdoor SF6 Circuit Breaker

LW-126 type outdoor high voltage alternating current sulfur hexafluoride circuit breaker (hereinafter referred to as the circuit breaker) is a kind of outdoor high-voltage switchgear equipment with three poles AC SOHzand it adopts SF6 gas as arc extinguishing and insulation medium. It can be used for the separation and combination of rated current and fault current, capacitor bank, and switching circuit, and it can also be used as aninterconnecting breaker so as to realize the control and protection of transmission lines and equipment, especially suitable for frequent operation.The circuit breaker is equipped with CT20 type spring operation mechanism.This circuit breaker complies with the requirements of IEC 62271-100. Lw36-126 3150-40 self-energized Ac high-voltage sulfur hexafluoride circuit breaker is an outdoor product, suitable for altitudes not exceeding 2,ooo meters (products can be designed for altitudes above 3,ooo meters), and the ambient temperature is not lower than -40°c. In the Ac 50Hz power grid with a maximum voltage of 126KV in areas with a pollution level no higher than Level Iv, it is used to cut off rated current, fault current or conversion lines to achieve power control.For system control and protection, it can also be used as a contact circuit breaker This product uses sF6 gas as arc extinguishing and insulating medium, adopts the most advanced self-energy arc extinguishing technology in the world, and is equipped with a new spring operating mechanism. It has the characteristics of long electrical life, low operating power, low noise, and high reliability., with its simple structure, small size and long maintenance cycle, it can completely replace the same type of imported products in the current process of oil-free and large-capacity power equipment.
24kV Outdoor High-voltage Intelligent Three Phase Pole Mounted Vacuum Circuit Breaker Auto Recloser

24kV Outdoor High-voltage Intelligent Three Phase Pole Mounted Vacuum Circuit Breaker Auto Recloser

ZW32-24 outdoor AC high-voltage vacuum circuit breaker (hereinafter referred to as circuit breaker) is rated voltage of 24kV, 50Hz three-phase AC outdoor power distribution equipment. This product is absorbing foreign advanced technology. Based on the dry domestic raw materials and factory art, the 24kV outdoor high-voltage switchgear suitable for China's national conditions has been successfully developed. Compared with similar international products, it has the characteristics of miniaturization, maintenance free and intellectualization. At the same time, the product has no pollution to the surrounding environment and is a green environmental protection product. The circuit breaker complies with technical standards such as gb1984-2003 high voltage AC circuit breaker, DL t402-2007 technical conditions for ordering high voltage AC circuit breaker and DL / t403-2000 technical conditions for ordering 12kV ~ 40.5kV high voltage vacuum circuit breaker .
Richge is a professional Vacuum Circuit Breaker Series manufacturer and supplier in China. If you're interested in our low price products, please contact us.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept